Glazing


Window Glazing

 

Glass Pane Options

Security Glass P4A Security Glass P4A

sun-protection-glassSun protection glass coating on level 2

thermal-insulation-glassThermal insulation glass coating on level 3

acoustic-insulationAcoustic insulation level 4, STC 40

acoustic-insulation-level6Acoustic insulation level 6, STC 51

Glass Windows Features

SECURITY

Glass for personal and property protection EN1062

 

UV PROTECTION

Sun protection in various intensities

 

THERMAL INSULATION

0,5 - 1,1 W/m2K
0,09 - 0,19 u-value

 

ACOUSTIC INSULATION

1: 25-29 dB
2: 30-34 dB
3: 35-39 dB
4: 40-44 dB
5: 45-49 dB
6: 50+ dB

Thermal Insulation

 

Effective November 2015

CURRENT NUMBER NAME TOTAL THICKNESS (OUT-AIR-IN) COATING ON LEVEL # TYPE OF COATED PANE NFRC_ID of COATED PANE MIN SASH THICKNESS WEIGHT (kg/m²) U(g) mit Argon NFRC 100-2010 U-VALUE NFRC 100-2010 WITH 90% ARGON R-VALUE NFRC 100-2010 WITH 90% ARGON SC SHGC

DAYLIGHT TRANS-MITTANCE

STC % UV RADIATION REDUCTION
34 Standard Insulated "Double Hung - "LowE" (22mm) 4-14-4 3 SGG Planitherm Ultra N 4mm 11333 59 20 1.42

.25

4.00 0.70 0.61 80 30 68
35 Custom thin double hung "no muntins", "LowE" max. 9 ft², not tempered (13mm) 3-6-4 3 SGG Planitherm Ultra N 4mm 11333 46

17.5

1.94 .34 2.93 0.70 0.61 80 29 68
36 DC Standard Insulated Double Hung "LowE" (26.2mm) 10.2-12-4 5 SGG Planitherm Ultra N 4mm 11333 59 33 1.37 0.24 4.14 0.63 0.55 78 37 99
37 DC Insulated Double Hung w. Grey tint glass LowE (26.2mm) 10.2-12-4 exterior pane Low-E on #5 SGG Parsol Grey 4mm SGG Planitherm Ultra N 4mm 11089? 11333 59 33 1.37 0.24 4.14 0.46 0.40 49 37 99
38 DC Insulated Double Hung w. Bronze tint glass LowE (26.2mm) 10.2-12-4 exterior pane Low-E on #5 SGG Parsol Bronze 4mm SGG Planitherm Ultra N 4mm 11074? 11333 59 33 1.37 0.24 4.14 0.48 0.42 54 37 99
39 DC Insulated Double Hung Solar control SGG XTREME 60-28 II (28.2mm) 12.2-12-4 4 SGG Cool-Lite XTREME 60-28II 6mm 11403 61 38 1.3 0.23 4.37 0.28 0.24 60 37 99
39.1 DC Insulated Double Hung Solar control SEMCO Klima 600 (28.2mm) 10.2-12-4 4 SEMCO Klima 600 not listed 59 33 1.3 0.23 4.37 0.31 0.27 58 37 99
40 DC Insulated Double Hung Solar control SGG Cool-Lite 165II (28.2mm) 12.2-12-4 4 SGG Cool-Lite 165II 6mm 11060 61 38 1.3 0.23 4.37 0.33 0.29 60 37 99
40.1 DC Insulated Double Hung Solar control SEMCO Klima 500 (28.2mm) 10.2-12-4 4 SEMCO Klima 500 not listed 59 33 1.3 0.23 4.37 0.28 0.24 49 37 99

99,9% UV radiation reduction only with special interlayer for UV radiation !!
STC values in brackets without sound test certification

Dade County Sunprotection Pane

combineutral6132level4

 

TISCHLER DC INSULATED - COMBI NEUTRAL 61/32 LEVEL 4

Thermal transmittance u-value: 0,25
Total solar energy transmittance (g-value): 32 %
Solar heat gain coefficient (SHGC)*: 27 %*
Shading Coefficient (g-value / 0.87): 37 %*
Light transmittance: 60 %
UV-Absorption: 95 %

combineutral6132level5

 

TISCHLER DC INSULATED - COMBI NEUTRAL 61/32 LEVEL 5

Thermal transmittance u-value: 0,21
Total solar energy transmittance (g-value): 43 %
Solar heat gain coefficient (SHGC)*: 37 %*
Shading Coefficient (g-value / 0.87): 50 %*
Light transmittance: 60 %
UV-Absorption: 95 %

parsolgrayexteriorpane

 

TISCHLER DC INSULATED - PARSOL GRAY EXTERIOR PANE

Thermal transmittance u-value: 0,23
Total solar energy transmittance (g-value): 34 %
Solar heat gain coefficient (SHGC)*: 29 %*
Shading Coefficient (g-value / 0.87): 39 %*
Light transmittance: 43 %
UV-Absorption: 96 %

*) Attention: The Solar heat gain coefficient has been calculated (g-value x 0,85 = SHGC). It is an approximate value. Although an initial, rough value for this coefficient can be approximately estimated using the solar heat gain coefficient of the glazing and attenuation factor of the shading system, such an rough estimate cannot take system specific properties into account, such as high levels of reflection from specular elements.